Unlike traditional solutions, signal transmission via the network no longer requires PLC or PC control. The hardware of the network controller IO controller can automatically map all physical switch signals without the need for ladder diagram or C language programming. With a network IO controller, input signals can be easily transmitted to the other end of the network via Ethernet, eliminating the need for programming or a separate controller for control.

Zongheng Intelligent Control 4IO network controller can transmit switching signals through the IP network, which can completely replace the existing cable-based signal transmission solutions. This product has 4DI, 4DO and 4AI and an Ethernet port. Using 4IO network controllers in pairs can transmit 4 sets of input and output signals to a PLC or DCS control system through the network.

Características

● 4 digital inputs, 4 digital outputs, and 4 analog inputs;

● DO follows AI/DI remotely, and logic can be configured freely;

●Transmit physical signals through Ethernet;

● Point-to-point/point-to-multipoint networking communication;

● Modbus TCP/RTU adaptive;

● I/O is completely isolated from the system;

● The power supply has good overcurrent, overvoltage, and anti-reverse connection protection functions;

● Rich indicator lights, comprehensive view of status, timely troubleshooting;

● Software and hardware dual watchdogs ensure stable operation of the equipment.

Technical Parameters

Parámetros de red
Tipo de red Ethernet
Número de puertos de red (10/100M) LAN*1
Tipo de puerto de red Señal Ethernet RJ45
Protección contra el aislamiento electromagnético 15KV electromagnetic isolation
Cross-connect automatic switching
Transformador de red externo innecesario
puerto serie
Número de puertos RS485*1
estándar RS485: bloque de terminales de 2 posiciones (A, B)
velocidad en baudios 600~921600bps
bits de datos 8,9
Bit de parada 0.5 , 1 , 1.5 , 2
Dígito de control NONE (sin bit de paridad) EVEN (paridad par) ODD (paridad impar)
DO
Número de interfaces 4 relay outputs
estándar (NO, NC, COM)*4
AC 250V 10A
DC 30V 10A
Durabilidad mecánica 10^7
Appliance durability 10^5
DI (dry node)
Número de interfaces 6
estándar DI*6, COM*1
DI (wet node)
Número de interfaces 6
estándar DI*6, COM*1
examination range 5~50V->High 0~2V->Low
PI
Número de interfaces 2
estándar PI*2, COM*1
examination range 10000Hz
AI
Número de interfaces 4
estándar AI*4, COM*2
examination range 4~20 mA
suministro eléctrico
Operating Voltage 9~36V
Working current

200mA(aver)/340mA(max)@9V

50mA(aver)/85mA(max)@36V

examination range 10000Hz
EMC level
ESD IEC61000-4-2, Nivel 4
sobretensión

IEC61000-4-2, Nivel 3

pulso de grupo IEC61000-4-2, Nivel 3
Mechanical structure
Tamaño del equipo 159.5*115.5*27.6mm(L*W*H)
concha have