EG8208 – 8 Serial Ports Edge Gateway

8 serial ports edge computing data bi-directional transmission multiple modes of operation Modbus RTU / TCP interoperability and customized JSON format reporting.

Interface type: 8RS485/8DO/1LAN

Protocol support: Modbus/PLC/RTU/TCP/MQTT/HJ212/PLC ……

Network type: 4G

Positioning support: None

Catégorie :

Description

EG8208 is a professional 8-channel independent isolated RS485 communication controller. With Modbus and JSON support, flexible TCP/IP and UDP switching, built-in monitoring, and self-diagnostic features, it can be widely used in industrial automation, building management, and other fields. Provide users with excellent data acquisition and device management solutions.

EG8208---EN_02
EG8208---EN_03
EG8208---EN_04
EG8208---EN_05
EG8208---EN_06
EG8208---EN_08
EG8208---EN_09
EG8208---EN_10
EG8208---EN_11
EG8208---EN_12
EG8208---EN_13
EG8208---EN_15
EG8208---EN_16
EG8208---EN_17
EG8208---EN_18
EG8208---EN_19
EG8208---EN_20
EG8208---EN_21
EG8208---EN_22

EV Series and EG8100/ G8000/ EG8000mini Edge Computing Gateway 4G bands

 

 

Module TyleFrequency Bands
EC200A-CNLTE-FDD: B1/B3/B5/B8
LTE-TDD: B34/B38/B39/B40/B41
WCDMA: B1/B5/B8
GSM:B3/B8
EC25-EUXLTE FDD: B1/B3/B7/B8/B20/B28A
LTE TDD: B38/B40/B41
WCDMA: B1/B8
GSM: B3/B8
EC25-AFLTE FDD: B2/B4/B5/B12/B13/B14/B66/B71
WCDMA: B2/B4/B5
EC25-AULTE FDD: B1/B2/B3/B4/B5/B7/B8/B28
LTE TDD: B40
WCDMA: B1/B2/B5/B8
GSM: B2/B3/B5/B8
EG25-GLTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/
B19/B20/B25/B26/B28
LTE TDD: B38/B39/B40/B41
UMTS: B1/B2/B4/B5/B6/B8/B19
GSM: B2/B3/B5/B8

 

EV Series and EG8000 Series Edge Computing Gateway PLC Protocols

La passerelle est classée selon la structure hiérarchique marque->protocole->modèle, et des modèles d'API représentatifs sont sélectionnés pour être testés dans chaque catégorie. Les autres modèles pris en charge proviennent des documents officiels. Remarque : la passerelle prend en charge le protocole standard MOBUDS RTU/TCP, qui est pris en charge par tous les automates courants. (Par exemple, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

MarqueProtocoleInterfaceModèle PLC
SIEMENSConseils :Siemens, dans la vente de la série, prend en charge la communication par protocole S7, il est recommandé d'utiliser la communication par protocole S7.
S7EthernetSérie S7-S200smart, Série S7-S200, Série S7-S300, Série S7-S400, Série S7-S1200, Série S7-S1500
PPIPort sérieSérie S7-200
MELSECConseils :Mitsubishi utilise principalement le protocole MC pour la communication, les séries FX5, FX3, Q, etc. sont testées.
EtherNet/IPEthernetSérie FX5-ENET/IP, série RJ71EIP91, série QJ71EIP71
MC-1E/MC-3EEthernetSérie FX5, série RJ71EN71, série RnENCPU, série LJ71E71, série QJ71E71, série QnUCPU, série FX3
MODBUS TCPEthernetSérie FX5, série RJ71EN71, série RnENCPU, série LJ71E71, série QJ71E71
MC-3CPort sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24
MODBUS RTUPort sérieSérie FX5, série RJ71C24, série LJ71C24, série QJ71C24, série FX3
FxLinksPort sérieSérie FX3, Série FX2, Série FX1, Série FX0
FxSerialPort sérieSérie FX3, Série FX2, Série FX1, Série FX0
OMRONConseils :Omron utilise principalement le protocole Fins pour la communication.
EtherNet/IPEthernetSérie NX7, série NX1, série NX1P, série NJ, CJ1W-EIP21
PalmesEthernetSérie CP, série CS, série CJ, série CV
HostLinkPort sérieSérie CP, série CS, série CJ, série CV, série C
LSisConseils :LS utilise principalement le protocole FEnet/Cnet pour la communication.
XGB FEnetEthernetSérie XGB (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetSérie XGT (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetPort sérieSérie XGB (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetPort sérieSérie XGT (XGL-CH2A, XGL-C21A, XGL-C41A)

 

MarqueProtocoleInterfaceModèle PLC
AllenBrandlyConseils :Rockwell utilise principalement le protocole CIP, DF1 pour la communication.
EtherNet/IPEthernetSérie ControlLogix, série CompactLogix, série Micro800 (820, 850, 870)
DF1Port sérieSérie ControlLogix, série CompactLogix (module 5069-SERIAL), série Micro800 (820, 830, 850, 870)
Série SLC (500, 5/03, 5/04, 5/05) , Série Micro-Logix (1000, 1100, 1200, 1500)
BeckhoffConseils :Beckhoff utilise principalement le protocole ADS pour la communication.
ADSEthernetSérie CX, TwinCAT2, TwinCAT3
InovanceConseils :Inovance adopte principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie AC, série AM, série H5U, série H3U
MODBUS RTUPort sérieSérie AC, Série AM, Série H5U, Série H3U, Série H1U
KeyenceConseils :Keyence utilise principalement le protocole KV pour la communication.
MC-3EEthernetSérie KV-8000, Série KV-7000, Série KV-5500, Série KV-5000
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A et autres unités Ethernet
KVEthernet
KVPort sérieKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicConseils :Panasonic utilise principalement le protocole Mewtocol pour la communication.
MC-3EEthernetSérie FP7, série FP0H, série FP-XH
MewtocolEthernetSérie FP7, série FP0H, série FP-XH
MewtocolPort sérieSérie FP7, série FP0H, série FP-XH, série FP-X0, série FP0R
DeltaConseils :Delta utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie AH, série AS, série AX-3, série DVP (Ethernet intégré)
MODBUS RTUPort sérieSérie AH, Série AS, Série AX-3, Série DVP
XinJEConseils :XinJE utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie CCSD, série XA, série XS, série XG, série XL
MODBUS RTUPort sérieSérie CCSD, série XA, série XS, série XG, série XL, série XC, série XD
MegMeetConseils :MegMeet utilise principalement le protocole MODBUS pour la communication.
MODBUS TCPEthernetSérie MC5100, série MC280, série MC200, série MC100, série MC80
MODBUS RTUPort sérieSérie MC5100, série MC280, série MC200, série MC100, série MC80
YaskawaConseils :Yaskawa utilise principalement le protocole MEMOBUS pour la communication (prend en charge le S7).
MemobusEthernetSérie GL120/130, Série GL60, Série MP3000, Série MP2300, Série Z1000
FatekConseils :Fatek utilise principalement le protocole Fatek pour la communication.
FatekPort sérieSérie FBs
VigueurConseils :Vigor utilise principalement le protocole privé VS pour communiquer.
VSPort sérieSérie VS
FujiConseils :Fuji utilise principalement le protocole SPH/SPB pour les communications.
SPHEthernetSérie SPH
SPBPort sérieSérie SPB

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.
Saisissez les détails du produit tels que la configuration de l'interface, l'environnement, etc. et d'autres exigences spécifiques pour recevoir un devis précis.
X

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.
Saisissez les détails du produit tels que la configuration de l'interface, l'environnement, etc. et d'autres exigences spécifiques pour recevoir un devis précis.

fr_FRFrench
Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.
Saisissez les détails du produit tels que la configuration de l'interface, l'environnement, etc. et d'autres exigences spécifiques pour recevoir un devis précis.