Product Introductie
High reliability
Producteigenschappen
Logic follows – local logic Logic follows – local logic Local logic operations do not need to rely on the cloud DO follows DI forward DO follows DI in reverse Greater than or equal to the threshold triggers DO Less than or equal to the threshold triggers DO |
Logic following, logic between devices Point-to-point logic following Multiple devices can be combined arbitrarily, and multiple channels can be followed arbitrarily. |
Timing trigger A time point (Beijing time) can be set to trigger restart or switch actions · Scheduled restart After enabling the socket, set a scheduled action and restart regularly to ensure that the device is effectively connected. No longer do you have to travel across mountains and rivers just to restart your equipment, achieving true 24/7 non-stop service. · Set open close Open or close the DO switch at regular intervals for flood discharge, power on, lighting, etc. |
Support 4-way socket The collected data can be sent to 4 servers at the same time. |
Support multiple protocols Compatible with Modbus RTU/TCP and JSON protocols Support MQTT, TCP, UDP multiple protocols |
Product topology
Model comparison
productafbeelding | Netwerk/Model | interface | Functie |
4G-communicatie via volledig netwerk ZHC492CG | 4DI/4DO/4AI/1RS485 | Ondersteunt meerdere systemen voor plaatsbepaling per satelliet: GPS, Beidou, QZSS Voorwaardelijke controle Automatisch ophalen Timingcontrole | |
4G-communicatie via volledig netwerk ZHC493C | 2DI/1DO/1AI/1RS485 | Modbus RTU/TCP adaptief Droge en natte node IO-detectie lokale logische bewerkingen Configuratiesoftware docking 4-weg stopcontact | |
4G-communicatie via volledig netwerk ZHC492C | 4DI/4DO/4AI/1RS485 | Een IO-netwerkproduct met 4 kanalen relaisuitgang (COM, NO, NC), 4 kanalen analoge hoeveelheiddetectie (stroom 4~20mA) en 1 kanaal seriële poorttransmissie, compatibel met Modbus RTU/TCP-protocol. | |
4G-communicatie via volledig netwerk ZHC4931 | 1RS485/232/2DI/1DO/1AI | Ondersteunt lokale logische verwerking, automatische verzameling en actieve rapportage, Modbus RTU/TCP-adaptatie, automatische rapportage van kalibratiedrempels, koppeling van configuratiesoftware en detectie van natte en droge node IO. | |
4G-communicatie via volledig netwerk ZHC4921 | 4DI/4DO/4AI/1RS485 | Ondersteunt lokale logische bewerkingen, automatische verzameling en actieve rapportage, Modbus RTU/TCP-adaptatie, automatische rapportage van kalibratiedrempels, configuratiesoftware docking, natte en droge node IO-detectie en andere speciale functies. | |
4G-communicatie via volledig netwerk ZHC4922 | 4DI/4DO/4AI/1RS48 | MQTT RTU/TCP adaptief, automatische kalibratie drempelrapportage, configuratie software docking, droge en natte node IO detectie en andere speciale functies | |
4G-communicatie via volledig netwerk ZHC4941 | 8DO/8DI/8AI/485/232 | Ondersteunt lokale logische bewerkingen, automatische verzameling en actieve rapportage, Modbus RTU/TCP-adaptatie, automatische rapportage van kalibratiedrempels, configuratiesoftware docking, natte en droge node IO-detectie en andere speciale functies. |
Ethernet ZHC1921 | RS485/4DI/2PIN/4DO/4AI | Ondersteunt 4-weg Socket, Modbus RTU/TCP adaptive, lokale logische verwerkingsberekeningen, automatische verzameling en actieve rapportage, DO remote follow AI/DI, configuratiewolk real-time monitoring PLC, automatische IP-adres acquisitie, DNS domeinnaamresolutie en andere speciale functies. | |
Ethernet ZHC1931 | RS485/RS232/2DI/1DO/1AI | Ondersteunt 4-weg Socket, Modbus RTU/TCP adaptief, lokale logische verwerking, automatische verzameling en actieve rapportage, DO op afstand volgen AI/DI, configuratiewolk real-time monitoring PLC, automatische acquisitie van IP-adres |
LoRa-netwerk | 1RS485/4DI/2DO | Ondersteunt AES-communicatie-encryptie. Het gebruik van de seriële poort voor verzenden en ontvangen verlaagt de drempel voor draadloze toepassingen en maakt gegevensoverdracht van de seriële poort naar LoRa mogelijk. |
Other introduction
The switching module developed by Zongheng Intelligent Control is often used to collect switching signals from on-site input devices (such as buttons, travel switches, temperature control switches, liquid level switches, etc.), convert the signals into low-voltage signals inside the PLC, and implement PLC Electrical isolation of internal and external signals.
In addition to the above-mentioned DI (switch input) interface, it also provides DO (switch output), which can be used for remote control, such as remote control of pump stations, remote control of street lights, etc.