AllenBrandly | Tips: | | Rockwell mainly uses CIP, DF1 protocol for communication. |
EtherNet/IP | Ethernet | ControlLogix Series, CompactLogix Series, Micro800 Series (820, 850, 870) |
DF1 | Serial port | ControlLogix Series, CompactLogix Series (5069-SERIAL module) , Micro800 Series (820, 830, 850, 870)
SLC Series (500, 5/03, 5/04, 5/05) , Micro-Logix Series (1000, 1100, 1200, 1500) |
Beckhoff | Tips: | | Beckhoff mainly uses the ADS protocol for communication. |
ADS | Ethernet | CX Series, TwinCAT2, TwinCAT3 |
Inovance | Tips: | | Inovance mainly adopts MODBUS protocol for communication. |
MODBUS TCP | Ethernet | AC Series, AM Series, H5U Series, H3U Series |
MODBUS RTU | Serial port | AC Series, AM Series, H5U Series, H3U Series, H1U Series |
Keyence | Tips: | | Keyence mainly uses the KV protocol for communication. |
MC-3E | Ethernet | KV-8000 Series, KV-7000 Series, KV-5500 Series, KV-5000 Series
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A and other Ethernet units |
KV | Ethernet |
KV | Serial port | KV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V |
Panasonic | Tips: | | Panasonic mainly uses the Mewtocol protocol for communication. |
MC-3E | Ethernet | FP7 Series, FP0H Series, FP-XH Series |
Mewtocol | Ethernet | FP7 Series, FP0H Series, FP-XH Series |
Mewtocol | Serial port | FP7 Series, FP0H Series, FP-XH Series, FP-X0 Series, FP0R Series |
Delta | Tips: | | Delta mainly uses MODBUS protocol for communication. |
MODBUS TCP | Ethernet | AH Series, AS Series, AX-3 Series, DVP Series (built-in Ethernet) |
MODBUS RTU | Serial port | AH Series, AS Series, AX-3 Series, DVP Series |
XinJE | Tips: | | XinJE mainly uses MODBUS protocol for communication. |
MODBUS TCP | Ethernet | CCSD Series, XA Series, XS Series, XG Series, XL Series |
MODBUS RTU | Serial port | CCSD Series, XA Series, XS Series, XG Series, XL Series, XC Series, XD Series |
MegMeet | Tips: | | MegMeet mainly uses MODBUS protocol for communication. |
MODBUS TCP | Ethernet | MC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series |
MODBUS RTU | Serial port | MC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series |
Yaskawa | Tips: | | Yaskawa mainly uses the MEMOBUS protocol for communication (supports S7) . |
Memobus | Ethernet | GL120/130 Series, GL60 Series, MP3000 Series, MP2300 Series, Z1000 Series |
Fatek | Tips: | | Fatek mainly uses the Fatek protocol for communication. |
Fatek | Serial port | FBs Series |
Vigor | Tips: | | Vigor mainly uses the VS private protocol for communication. |
VS | Serial port | VS Series |
Fuji | Tips: | | Fuji mainly uses the SPH/SPB protocol for communications. |
SPH | Ethernet | SPH Series |
SPB | Serial port | SPB Series |