EV8010

High-performance industrial control all-in-one PC.

  • Display Screen : 10.1”16:9 TFT LCD
  • Pixels : 1280px(H) * 800px(V)
  • Serial Port : 1*RS232+2*R485
  • Ethernet : 1*WAN(GE)+ 1*LAN(FE)
  • OS : Linux
  • Storage : 16GB

Categories: ,

Description

The EV series is an Industrial Computer, it not only inherits all the functions of the EG series, but also supports WEB configuration (VISION), paired with a high definition LCD touch screen, to meet the needs of different IoT application scenarios.

HMI detail page EN_1HMI detail page EN_2HMI detail page EN_3HMI detail page EN_4HMI detail page EN_5HMI detail page EN_6HMI detail page EN_7HMI detail page EN_8HMI detail page EN_9HMI detail page EN_10HMI detail page EN_11HMI detail page - -EN_12

EV Series and EG8100/ G8000/ EG8000mini Edge Computing Gateway 4G bands

 

 

Module TyleFrequency Bands
EC200A-CNLTE-FDD: B1/B3/B5/B8
LTE-TDD: B34/B38/B39/B40/B41
WCDMA: B1/B5/B8
GSM:B3/B8
EC25-EUXLTE FDD: B1/B3/B7/B8/B20/B28A
LTE TDD: B38/B40/B41
WCDMA: B1/B8
GSM: B3/B8
EC25-AFLTE FDD: B2/B4/B5/B12/B13/B14/B66/B71
WCDMA: B2/B4/B5
EC25-AULTE FDD: B1/B2/B3/B4/B5/B7/B8/B28
LTE TDD: B40
WCDMA: B1/B2/B5/B8
GSM: B2/B3/B5/B8
EG25-GLTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/
B19/B20/B25/B26/B28
LTE TDD: B38/B39/B40/B41
UMTS: B1/B2/B4/B5/B6/B8/B19
GSM: B2/B3/B5/B8

 

EV Series and EG8000 Series Edge Computing Gateway PLC Protocols

The gateway is categorized according to the hierarchical structure of brand->protocol->model, and representative PLC models are selected for testing in each category. The rest of the supported models are from the official documents. Note: The gateway supports the standard MOBUDS RTU/TCP protocol, which is supported by all mainstream PLCs. (For example, HollySys, Haiwell, Yokogawa, Runpower, etc.)

 

BrandProtocolInterfacePLC Model
SIEMENSTips:Siemens in the sale of the series all support S7 protocol communication, it is recommended to use the S7 protocol communication.
S7EthernetS7-S200smart, S7-S200 Series, S7-S300 Series, S7-S400 Series, S7-S1200 Series, S7-S1500 Series
PPISerial portS7-200 Series
MELSECTips:Mitsubishi mainly uses MC protocol for communication, FX5 Series, FX3 Series, Q Series, etc. are tested.
EtherNet/IPEthernetFX5-ENET/IP Series, RJ71EIP91 Series, QJ71EIP71 Series
MC-1E/MC-3EEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series, QnUCPU Series, FX3 Series
MODBUS TCPEthernetFX5 Series, RJ71EN71 Series, RnENCPU Series, LJ71E71 Series, QJ71E71 Series
MC-3CSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series
MODBUS RTUSerial portFX5 Series, RJ71C24 Series, LJ71C24 Series, QJ71C24 Series, FX3 Series
FxLinksSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
FxSerialSerial portFX3 Series, FX2 Series, FX1 Series, FX0 Series
OMRONTips:Omron mainly uses the Fins protocol for communication.
EtherNet/IPEthernetNX7 Series, NX1 Series, NX1P Series, NJ Series, CJ1W-EIP21
FinsEthernetCP Series, CS Series, CJ Series, CV Series
HostLinkSerial portCP Series, CS Series, CJ Series, CV Series, C Series
LSisTips:LS mainly uses FEnet/Cnet protocol for communication.
XGB FEnetEthernetXGB Series (XBC/XEC U, XBL-EMTA)
XGK FEnetEthernetXGT Series (XGL-EFMT, XGL-EFMF, XGL-EH5T)
XGB CnetSerial portXGB Series (XBC/XEC U, XBL-C21A, XBL-C41A)
XGK CnetSerial portXGT Series (XGL-CH2A, XGL-C21A, XGL-C41A)

 

BrandProtocolInterfacePLC Model
AllenBrandlyTips:Rockwell mainly uses CIP, DF1 protocol for communication.
EtherNet/IPEthernetControlLogix Series, CompactLogix Series, Micro800 Series (820, 850, 870)
DF1Serial portControlLogix Series, CompactLogix Series (5069-SERIAL module) , Micro800 Series (820, 830, 850, 870)
SLC Series (500, 5/03, 5/04, 5/05) , Micro-Logix Series (1000, 1100, 1200, 1500)
BeckhoffTips:Beckhoff mainly uses the ADS protocol for communication.
ADSEthernetCX Series, TwinCAT2, TwinCAT3
InovanceTips:Inovance mainly adopts MODBUS protocol for communication.
MODBUS TCPEthernetAC Series, AM Series, H5U Series, H3U Series
MODBUS RTUSerial portAC Series, AM Series, H5U Series, H3U Series, H1U Series
KeyenceTips:Keyence mainly uses the KV protocol for communication.
MC-3EEthernetKV-8000 Series, KV-7000 Series, KV-5500 Series, KV-5000 Series
KV-EP21V, KV-LE21V, KV-LE20V, KV-LE20A and other Ethernet units
KVEthernet
KVSerial portKV-7300, KV-3000, KV-1000, KV-700, KV Nano, KV-L21V, KV-L20V
PanasonicTips:Panasonic mainly uses the Mewtocol protocol for communication.
MC-3EEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolEthernetFP7 Series, FP0H Series, FP-XH Series
MewtocolSerial portFP7 Series, FP0H Series, FP-XH Series, FP-X0 Series, FP0R Series
DeltaTips:Delta mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetAH Series, AS Series, AX-3 Series, DVP Series (built-in Ethernet)
MODBUS RTUSerial portAH Series, AS Series, AX-3 Series, DVP Series
XinJETips:XinJE mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetCCSD Series, XA Series, XS Series, XG Series, XL Series
MODBUS RTUSerial portCCSD Series, XA Series, XS Series, XG Series, XL Series, XC Series, XD Series
MegMeetTips:MegMeet mainly uses MODBUS protocol for communication.
MODBUS TCPEthernetMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
MODBUS RTUSerial portMC5100 Series, MC280 Series, MC200 Series, MC100 Series, MC80 Series
YaskawaTips:Yaskawa mainly uses the MEMOBUS protocol for communication (supports S7) .
MemobusEthernetGL120/130 Series, GL60 Series, MP3000 Series, MP2300 Series, Z1000 Series
FatekTips:Fatek mainly uses the Fatek protocol for communication.
FatekSerial portFBs Series
VigorTips:Vigor mainly uses the VS private protocol for communication.
VSSerial portVS Series
FujiTips:Fuji mainly uses the SPH/SPB protocol for communications.
SPHEthernetSPH Series
SPBSerial portSPB Series

Contact Us

Contact Us