485 protocol and modbus protocol are commonly used industrial communication protocols and are widely used in the field of industrial automation. They play an important role in control systems, data acquisition, instrumentation, etc., but there are also some differences between them.

The difference between 485 protocol and modbus protocol

Difference 1: The 485 protocol is a physical layer communication standard, while the modbus protocol is a data transmission protocol. The 485 protocol usually uses the RS-485 electrical standard, supports multi-point communication, and can realize communication between multiple devices. It is suitable for scenarios with high requirements for long-distance communication and anti-interference capabilities. The modbus protocol is an application layer protocol for traditional serial communication. It defines a master-slave structure communication method and can be flexibly applied to different physical layer transmission media, including RS-232, RS-485, Ethernet etc.

Difference 2: In practical applications, the 485 protocol is more used in point-to-point or point-to-multipoint communication scenarios. For example, in industrial control systems, communication between PLC, sensors, and actuators can be achieved through the 485 protocol to achieve data collection and transmission of control commands. The Modbus protocol is more used for data collection, monitoring and control applications in industrial automation systems because of its flexibility and versatility. Especially in the modern industrial Internet environment, data exchange between the equipment and the host computer can be realized through the Modbus protocol, which facilitates remote monitoring and management.

Difference 3: There are also some differences in performance and bandwidth between the 485 protocol and the modbus protocol. Generally, the 485 communication rate is between 1.2kbps and 10Mbps, while the modbus protocol can support higher communication rates, reaching 100Mbps or even higher. This means that the Modbus protocol is more suitable in some scenarios that require higher communication speed.

To sum up, there are certain differences between the 485 protocol and the Modbus protocol in communication standards, application scenarios and performance characteristics . Users need to make reasonable choices based on actual needs when choosing. If it is a scenario with high requirements for anti-interference capability and multi-point communication, you can choose the 485 protocol; if it is a data collection, monitoring and control application, and has high requirements for communication rate, you can choose the Modbus protocol. Of course, in actual applications, comprehensive selection can also be made based on specific circumstances, and even conversion and adaptation between the two protocols can be performed to meet different application needs.Related recommendations: CAN to 485 data corresponding analysis